CHAPTER 7A - REGULATIONS FOR LIMITED DENSITY OWNER-BUILT RURAL DWELLINGS


Sec. 7A-1. - Title.

This section shall be known and may be cited as the Regulations for Limited Density Owner-Built Rural Dwellings.

(Ord. No. 2875.).

Sec. 7A-2. - Purpose.

The purpose of this chapter is to provide minimum requirements for the protection of life, limb, health, property, safety, and welfare of the general public and the owners and occupants of limited density owner-built rural dwellings and appurtenant structures.

(Ord. No. 2875.)

Sec. 7A-3. - Intent and application.

The provisions of this chapter shall apply to the construction, enlargement, conversion, alteration, repair, use, maintenance, and occupancy of limited density owner-built rural dwellings and appurtenant structures.

It is the intent of this chapter that the requirements contained herein shall apply to seasonally or permanently occupied dwellings, hunting shelters, guest cottages, vacation homes and recreational shelters located in rural areas.

Owner-built rural dwellings shall be permitted only on parcels of at least 20 acres in size which parcels are designated in the Sonoma County General Plan as Undeveloped, General Agriculture, Orchards & Vineyards.

Construction shall be limited to one single family dwelling unit per parcel of land as shown on the Assessors Parcel Maps.

(Ord. No. 2875.)

Sec. 7A-4. - Existing buildings.

The provisions of this chapter regulating the erection and construction of dwellings and appurtenant structures shall not apply to existing structures as to which construction is commenced or approved prior to the effective date of this chapter. Requirements relating to use, maintenance, and occupancy shall apply to all dwellings and appurtenant structures approved for construction or constructed before or after the effective date of this chapter.

Existing structures shall be issued a Certificate of Occupancy by the Building Inspection Department upon meeting the requirements of this section.

(Ord. No. 2875.)

Sec. 7A-5. - Amendments to insure compliance.

For the purposes of this chapter the sale, lease, renting or employee occupancy of owner-built structures within three years of the issuance of a Certificate of Occupancy shall be presumptive evidence that the structure was erected for the purpose of sale, lease or renting.

(Ord. No. 2875.)

Sec. 7A-6. - Abatement of substandard buildings.

All structures or portions thereof which are determined by the enforcing agency to constitute a substandard building shall be declared to be a public nuisance and shall be abated by repair, rehabilitation, or removal in accordance with Health and Safety Code Sections l7980 through 17995 of this subsection. In cases of extreme hardship to owner-occupants of the dwellings, the appropriate local body should provide for deferral of the effective date of orders of abatement.

(Ord. No. 2875.)

Sec. 7A-7. - Board of appeals for limited density owner-built dwelling regulations.

Composition: The board of Appeals shall consist of five (5) members: one civil engineer, one sanitarian, one owner-builder, one alternate energy consultant, and one person-at-large. The board of appeals shall be appointed by and serve at the pleasure of the Sonoma County board of supervisors. The building official or designate should be the secretary of the board of appeals, without voting privilege.

Function and Authority: The board of appeals shall adopt reasonable rules and regulations for conducting its investigations and render all decisions and findings in writing to the appropriate administrative authority. The board shall also keep a record of all interpretations, decisions and findings rendered by said board or obtained by the board from the State Commission of Housing and Community Development and shall provide notice to the appellant of the board's decision. Such records shall be available for review by the public or any governmental agency. The board may rule in matters of interpretation and application of owner-built housing regulations, the suitability of alternate materials and methods of construction. Board decisions shall be in conformance with any applicable state or local statute or regulations.

(Ord. No. 2875.)

Sec. 7A-8. - Recordation of owner-built rural dwelling.

The Building Inspection Department shall record with the county recorder a "Certificate of Occupancy" for limited density owner-built rural dwelling upon approval of final inspection.

(Ord. No. 2875.)

Sec. 7A-9. - Constitutional and statutory validity.

It is the express purpose of this chapter to conform the regulations regarding the construction and use of limited density rural owner-built dwellings and appurtenant structures to the requirements of Article 1, Section 1, of the California State Constitution, and the statutes of the State of California. If any section, subsection, sentence, clause, or phrase of this chapter is, for any reason, held to be unconstitutional or contrary to California statutes, such ruling shall not affect the validity of the remaining portions of this chapter.

(Ord. No. 2875.)

Sec. 7A-10. - Violations.

The critical concern in the promulgation of this chapter is to provide for health and safety while maintaining respect for the law and voluntary compliance with the provisions of this chapter, and therefore, in the event that an order to correct a substandard condition is ignored, it is the intent of this section that civil abatement procedures should be the first remedy pursued by the enforcement agency.

(Ord. No. 2875.)

Sec. 7A-11. - Permits.

Permits shall be required for the construction of rural dwellings and appurtenant structures.

Exemptions: Permits shall not be required for small or unimportant work, or alterations or repairs that do not present a health or safety hazard, and which are in conformance with local zoning requirements or property standards. The determination, if any, of what work is properly classified as small or unimportant or without relation to health and safety hazards is to be made by the appropriate local agencies.

(Ord. No. 2875.)

Sec. 7A-12. - Issuance.

The application, plans, and other data filed by an applicant for a permit shall be reviewed by the appropriate enforcement agency to verify compliance with the provisions of this article. Where the enforcement agency determines that the permit applications and other data indicates that the structure(s) will comply with the provisions of this article, the agency shall issue a permit therefore to the applicant.

(Ord. No. 2875.)

Sec. 7A-13. - Application.

To obtain a permit, the applicant shall first file an application therefore with the designated enforcement agency. Permit applications shall contain the following information: (1) name and mailing address of the applicant; (2) address and location of the proposed structure(s); (3) a general description of the structure(s) which shall include mechanical installations with all clearances and venting procedures detailed, electrical installations, foundation, structural, and construction details; (4) a plot plan indicating the location of the dwelling in relation to property lines, other structures, sanitation and bathing facilities, water resources, and water ways; (5) approval for the installation of a private sewage disposal system or alternate waste disposal means from the local health enforcement agency; (6) a stipulation by the applicant that the building or structure is to be owner-built; (7) the signature of the owner or authorized agent; (8) the use or occupancy for which the work is intended; (9) and any other data or information as may be required by statute or regulation.

(Ord. No. 2875.)

Sec. 7A-14. - Plans.

Plans shall consist of a general description of the structure(s), including all necessary information to facilitate a reasonable judgment of conformance by the enforcing agency. This may include a simplified diagram of the floor plan, structural cross-section and site elevation in order to determine the appropriate dimensions of structural members. Architectural drawings and structural analyses shall not be required except for structures of complex design or unusual conditions for which the enforcement agency cannot make a reasonable judgment of conformance to this chapter based upon the general description and simplified plan(s).

(Ord. No. 2875.)

Sec. 7A-15. - Waiver of plans.

The enforcement agency may waive the submission of any plans if the agency finds that the nature of the work applied for is such that the reviewing of plans is not necessary to obtain compliance with this chapter.

(Ord. No. 2875.)

Sec. 7A-16. - Modifications.

Modifications to the design, materials, and methods of construction are permitted, provided that the structural integrity of the building or structure is maintained, the building continues to conform to the provisions of this chapter and the enforcement agency is notified in writing of the intended modification.

(Ord. No. 2875.)

Sec. 7A-17. - Permit validity.

Permits shall be valid, without renewal, for a minimum period of three years.

(Ord. No. 2875.)

Sec. 7A-18. - Inspections.

All construction or work for which a permit is required may be subject to inspection by the designated enforcement agency.

(Ord. No. 2875.)

Sec. 7A-19. - Issuance of inspections.

An inspection of the building or structure(s) shall be conducted after the structure(s) is completed and ready for occupancy, in order to determine compliance with the provisions of this chapter. Structures of conventional or simple construction shall be inspected at a single inspection.

(Ord. No. 2875.)

Sec. 7A-20. - Special inspections.

Additional inspections may be conducted under the following circumstances: An inspection may be conducted where there is a reasonable expectation that the footing will be subjected to serious vertical or lateral movement due to unstable soil conditions; or the application indicates that interior wall coverings or construction elements will conceal underlying construction, electrical or mechanical systems; or where an unconventional construction method is indicated which would preclude examination at a single inspection.

(Ord. No. 2875.)

Sec. 7A-21. - Inspection waivers.

Inspections may be waived by the enforcement agency for structures which do not contain electrical or mechanical installations or for alterations, additions, modifications or repairs that do not involve electrical or mechanical installations; or where the applicant stipulates in writing that the work has been conducted in compliance with the permit application and the provisions of this chapter.

(Ord. No. 2875.)

Sec. 7A-22. - Inspection requests and notice.

It shall be the duty of the applicant to notify the enforcement agency that the construction is ready for inspection and to provide access to the premises. Inspections shall be requested by the applicant at least (48) hours in advance of the intended inspection. It shall be the duty of the enforcement agency to notify or inform the applicant of the day during which inspection is to be conducted.

(Ord. No. 2875.)

Sec. 7A-23. - Certificate of occupancy.

After the structure(s) is completed for occupancy and any inspections which have been required by the enforcing agency have been conducted, and work approved, the enforcement agency shall issue a certificate of occupancy for such dwelling(s) and appurtenant structure(s) which comply with the provisions of this chapter.

(Ord. No. 2875.)

Sec. 7A-24. - Temporary occupancy.

The use and occupancy of a portion or portions of a dwelling or appurtenant structure prior to the completion of the entire structure shall be allowed, provided that approved sanitary facilities are available at the site, and that the work completed does not create any condition to an extent that endangers life, health, or safety of the public or occupants. The occupants of any such uncompleted structure shall assume sole responsibility for the occupancy of the structure or portion thereof.

(Ord. No. 2875.)

Sec. 7A-25. - Fees.

Fees may be required and collected by the enforcement agency to provide for the cost of administering the provisions of this chapter. It is the intent of this chapter that permit and inspection fee schedules be established to reflect the actual inspection and administrative cost resulting from the application of this chapter.

(Ord. No. 2875.)

Sec. 7A-26. - Definitions.

a.   Enforcing/Enforcement Agency. "Enforcing or enforcement agency" shall mean the permit and resource management department, unless otherwise specifically noted.
b.   Greywater. "Greywater" shall include all domestic waste water obtained from the drainage of showers, bathtubs, kitchen sinks, lavatories, and laundry facilities, exclusive of water utilized for the transport and disposal of body eliminations.
c.   Limited Density Rural Dwelling. "Limited density rural dwelling" is any structure consisting of one or more habitable rooms intended or designed to be occupied by one family with facilities for living and sleeping, with use restricted to rural areas that fulfills the requirements of this chapter.
d.   Owner-Built.
(a)   "Owner-built" shall mean constructed by any person or family who acts as the general contractor for, or as the provider of part or all of the labor necessary to build housing to be occupied as the principal residence of that person or family, and not intended for sale, lease, rent or employee occupancy.
(b)   For the purposes of this chapter, the sale, lease, renting or employee occupancy of owner-built structures within three (3) years of the issuance of a certificate of occupancy shall be presumptive evidence that the structure was erected for the purpose of sale, lease or renting.
e.   Rural. For the purposes of this chapter only, "rural" shall mean those unincorporated areas of counties designated and zoned by the appropriate local agency for the application of this chapter. Suitable areas may include those wherein the predominant land usage is agricultural and undeveloped.
f.   Sound Structural Condition. A structure shall be considered to be in "sound structural condition" when it is constructed and maintained in substantial conformance with accepted construction principles, technical codes, or performance criteria which provide minimum standards for the stressing of structural members; footing sizes when related to major load-bearing points; proper support of load-bearing members; nailing schedules where essential to general structural integrity; and provisions for adequate egress, ventilation, sanitation, and fire safety. Conditions which would not render a structure unsound are the minor deflections or elasticity of structural members, ceiling heights, size or arrangement of rooms, heating, plumbing, and electrification requirements, alternative materials, appliances or facilities, or methods of construction, or building designs that perform to protect health and safety for the application and purpose intended, and any other provisions of this chapter regulating the construction, use and occupancy of dwellings and appurtenant structures.
g.   Substandard Building. A "substandard building" is a structure or portion thereof in which there exists any condition to an extent that endangers the life, limb, health, or safety of the occupants. Except as amended by the provisions of this chapter, Chapter 10 of the Uniform Housing Code, 1976 Edition, as published by ICBO, shall be the determining criteria for compliance with the standards of this chapter and the defining of a substandard building.

(Ord. No. 4906 § 4(A), 1995; Ord. No. 2875.)

Sec. 7A-27. - General requirements.

Each structure shall be constructed and maintained in a sound structural condition to be safe and sanitary, and to shelter the occupants from the elements.

(Ord. No. 2875.)

Sec. 7A-28. - Intent of general requirements.

It shall be the purpose and intent of this chapter to permit the use of ingenuity and preferences of the builder, and to allow and facilitate the use of alternatives to the specifications prescribed by the Uniform Technical Codes to the extent that a reasonable degree of health and safety is provided by such alternatives, and that the materials, methods of construction, and structural integrity of the structure shall perform in application for the purpose intended. To provide for the application of this chapter, it shall be necessary for the enforcement agency to exercise reasonable judgment in determining the compliance of appropriate structures with the general and specific requirements of this article.

(Ord. No. 2875.)

Sec. 7A-29. - Technical codes to be a basis of approval.

Except as otherwise required by this chapter, dwellings and appurtenant structures constructed pursuant to this part need not conform with the construction requirements prescribed by the latest applicable editions of the Uniform Building, Plumbing, and Mechanical Codes, the National Electrical Code, or other applicable technical codes; however, it is not the intent of this section to disregard nationally accepted technical and scientific principles relating to design, materials, methods of construction, and structural requirements for the erection and construction of dwelling and appurtenant structures as are contained in the Uniform Technical Codes. Such codes shall be a basis for approval.

(Ord. No. 2875.)

Sec. 7A-30. - Construction requirements.

a.   Structural Requirements. Buildings or structures constructed pursuant to this chapter may be of any type of construction which will provide for a sound structural condition. Structural hazards which result in an unsound condition and which may constitute a substandard building are delineated by Section 1001 (c), Uniform Housing Code (most recent edition).
b.   Foundations. Pier foundations, stone masonry footings and foundations, pressure treated lumber, poles, or equivalent foundation materials or designs may be used provided that the bearing and lateral stability is sufficient for the purpose intended.
c.   Materials. Owner-produced or used materials and appliances may be utilized unless found not to be of sufficient strength or durability to perform the intended function; owner-produced or used lumber or shakes and shingles may be utilized unless found to contain dry rot, excessive splitting, or other defects obviously rendering the material unfit in strength or durability for the intended purpose.
d.   Mechanical Requirements. Fireplaces and heating and cooking appliances and gas piping installed in buildings constructed pursuant to this chapter shall be installed and vented in accordance with the requirements of Chapter 37 of the Uniform Building Code and Chapter 9 of the Uniform Mechanical Code and Chapter 12 of the Uniform Plumbing Code. Alternate materials and methods of venting shall be permitted if substantially equivalent in safety and durability. The latest edition of the various codes shall apply.
e.   Heating Capacity. A heating facility or appliance shall be installed in each dwelling subject to the provisions of this chapter; however, there shall be no specified requirement for heating capacity or temperature maintenance. The use of a solid fuel or solar heating device shall be deemed as complying with the requirements of this section. If non-renewable fuel is used in these dwellings, rooms so heated shall meet current insulation standards.
f.   Electrical Requirements. No dwelling or appurtenant structure constructed pursuant to this chapter shall be required to be connected to a source of electrical power, or wired, or otherwise fitted for electrification, except as set forth below in Section 7A-30. g. of this section.
g.   Installation Requirements. Where electrical wiring or appliances are installed, they shall be installed in accordance with the provisions of the National Electrical Code adopted by the State Housing and Community Development Commission for single family dwellings.

Exceptions to Installation Requirements. In structures where electrical usage is confined to one or more rooms of a structure, the remainder of the structure shall not be required to be wired or otherwise fitted for electrification unless the enforcement agency determines that electrical demands are expected to exceed the confinement and capacity of that room(s). In such instances, the enforcement agency may require further electrification of the structure.

It is the intent of this subsection to apply to buildings in which there exists a workshop, kitchen, or other single room which may require electrification, and where there is no expectation of further electrical demand. The enforcement agency shall, at the time of a permit application or other appropriate point, advise the applicant of the potential hazards of violating this section.

Service Limit. The main service equipment shall be limited in size to the intended load capacity of the installed electrical facilities.

h.   Room Requirements. There shall be no requirements for room dimensions provided that there is adequate light and ventilation and adequate means of egress. In single family dwellings not exceeding two stories in height where, due to the location or to the surrounding terrain, emergency rescue from the exterior is not feasible, egress windows from sleeping spaces may be omitted when an additional doorway or an approved exit escape hatch is provided for egress from such rooms. The doorways provided shall open directly to the exterior of the building or shall open onto corridors or passageways which lead to individual exterior exits. The corridors or passageways provided shall not cross nor shall they follow the same route in whole or in part of the building exterior. Approved exit escape hatches shall be installed in accordance with the terms of their approval.

Exception: Openable windows or exterior doors for emergency egress or rescue from sleeping rooms of a single-family dwelling may be omitted when such rooms are located on a mezzanine floor or loft area which is at least fifty percent (50%) open to the floor below. Such mezzanine or loft area shall have at least two (2) means of evacuation acceptable to the enforcing authority and may include stairways, ladders, escape hatches, or any other design or arrangement which will allow egress in the event of an emergency.

(Ord. No. 275.)

Sec. 7A-31. - Sanitation requirements.

Sanitation facilities, including the type, design, and number of facilities, as required and approved by the director of permit and resources management department, shall be provided to the dwelling sites. It shall not be required that such facilities be located within the dwelling.

(Ord. No. 4906 § 4(B) (part), 1995; Ord. No. 2875.)

Sec. 7A-32. - Plumbing specifications.

Where conventional plumbing, in all or in part, is installed within the structure, it shall be installed in accordance with the Uniform Plumbing Code (latest edition). Alternative materials and methods shall be permitted provided that the design complies with the intent of the code, and that such alternatives shall perform to protect health and safety for the intended purpose.

(Ord. No. 2875.)

Sec. 7A-33. - Sanitation facilities.

A water closet shall not be required when an alternate system is provided and has been approved by the director of permit and resources management department. Where an alternative to the water closet is installed, a system for the disposal or treatment of greywater shall be provided to the dwelling. Greywater systems shall be designed according to water availability, use and discharge. The design, use, and maintenance standards of such systems shall be the prerogative of the director of permit and resources management department.

A bathtub or shower and a lavatory, or alternate bathing and washing facility approved by the director of permit and resources management department, shall be provided to the dwelling site.

(Ord. No. 4906 § 4(B) (part), 1995; Ord. No. 2875.)

Sec. 7A-34. - Water supply.

a.   Potable Water. Potable water shall be available on the dwelling site, although such water need not be pressurized. Quantity of water to be in accordance with requirements established by the director of permit and resources management department. Where water delivery is pressurized, appropriate piping shall be installed in accordance with the provisions of this chapter.
b.   Supply for Fire Fighting. A minimum storage of two thousand (2,000) gallons shall be available. Storage may be in tanks, swimming pools, ponds or other similar storage facilities.

(Ord. No. 4906 § 4(B) (part), 1995; Ord. No. 2875.)